Schneider Electric Single-Channel Safety Switch Interlock Safety Relay, 24V dc, 2 Safety Contacts
Category: Schneider
Specifications
Selangor | Shah Alam | Subang Jaya | Tanjong Sepat | Banting | Semenyih | Tanjung Karang | Sabak | Sepang | Kajang | Balakong | Puncak Alam | Kapar | Kerling | Rasa | Bandar Baru Bangi | Putra Heights | Tanjong Malim | Kampung Sungai Lang | Cheras | Bangi | Batang Kali | Bukit Rotan | Salayang | Sekinchan | Seri Kembangan | Beranang | Kuang | Cyberjaya | Ampang Jaya | Serendah | Sungai Besar | Klang | Kuala Selangor | Petaling Jaya | Rawang | Batu Arang | Jenjarom | Bestari Jaya | Kuala Kubu Bharu | Sungai Pelek | Kuang | Puchong | Port Klang | Sungai Ayer Tawar | Dengkil | Sungai Buloh | Telok Panglima Garang | Kundang | Jugra | Bandar Sungai Buaya
Schneider Safety Switch Device Bandar utama
Schneider Safety Switch Device sri petaling
Schneider Safety Switch Device oug
Schneider Safety Switch Device klang lama kuchai lama
Details
-
Schneider Electric Preventa XPS-DM Safety Relays.
-
From Schneider Electric this is the Preventa XPSDM series of safety relays and safety modules designed for guard monitoring coded magnetic safety switches. The safety relays have 2 safety outputs and 2 solid state outputs signalling to the process PLC. Front facing LEDs allow you to monitor the circuit status. XPSDM Safety relays also monitor 2 independent sensors plus if you need to monitor more magnetic switches they can be connected in series parallel.
-
Safety relays from the XPSDM (XPSDMB….P) series include removable terminal blocks providing maximum machine maintenance.
-
Features & Benefits
-
Created and designed for guard monitoring, this range of XPS-DM safety relays are predominantly used for monitoring XCS-DMC and XCS-DMP coded magnetic safety switches.
-
When the XCS-DM safety switch is used in conjunction with the XPS-DM safety relay, together they offer a certified safety solution for guard monitoring
-
This range of safety relays allowed for multi-switch monitoring to Safety Category 4 solutions which is in accordance with EN954-1/ISO 13849-1
-
The XPS-DMB has the capabilities to monitor 2 independent sensors and modules whilst the XPS-DME can monitor 6 independent sensors and modules
-
2 safety outputs and 2 solid-state outputs for signalling to the process PLC
-
LEDs are positioned on the front face which provides signalling information on the monitoring circuit status.
-
Safety Level (Maximum).
-
PL e/Category 4 conforming to EN/ISO 13849-1 b.
-
SILCL 3 conforming to EN/IEC 62061.
View more about Schneider Electric Single-Channel Safety Switch Interlock Safety Relay, 24V dc, 2 Safety Contacts on main site